| Configure
a machine for our specific drying application |
Size: Choose
working capacity; for smaller sizes; please ask for details
on our lab blenders)?
Cubic Feet
or
Liters
|
Maximum
bulk density of the materials to be blended?
measured
in:
|
Does
the density change during processing such as increase significantly
due to liquid addition? Please
provide details:
|
Describe
the liquid to be dried off:
|
Would
you like the following utility packages quoted?
|
| |
| Note: Tumble
blenders are volumetric machines, that are not rated for a
specific mass of product such as one ton. They are rated for
a specific volume of material (the working capacity from above)
at a maximum bulk density. It is not correct however to take
the maximum density time the working volume to obtain a "weight
rating" for the unit. For example if we say a 60 cubic foot
(1,700 liter) working capacity unit is rated for 62 pounds
per cubic foot (1g/cc), we can not multiply the two to say
it is rated for 3,720 pounds (1,700 Kg). The reason we can
not is the next operator will have material weighing twice
as much and mistakenly decide to put in half the volume in
order to stay within the weight limitations. |
| If
you wish to provide us with the weight, we will size the unit
according to the bulk density. |
| Please choose
a vessel
shape: |
|
|
Please
select material of construction for product contact:
Any special contact material such as a coating:
|
| Internal pressure : full
vacuum?
PSIG
|
| ASME
code stamp:
|
| Product density
(cu/ft.)
|
| Operating temperature
(degrees farenheigt)
F |
| Heating Jacket |
| material of construction:
carbon steel
304SS
other
|
external finish:
other:
|
| jacket pressure (PSIG)
|
| ASME code stamp
|
| Operating temperature (degrees F)
|
| Jacket type
|
| Insulation Jacket |
| Sheathing material
|
| External finish
|
| Insulation material: fiberglass
Other:
|
| Purges |
| None
Nitrogen
Other
|
| |
| If High
Sheer bar is required, choose one of the following:
Slow speed High Sheer Bar (nominal 1,650 feet per minute [503 meters per minute]
blade peripheral tip speed) for breaking up loose agglomerates, lump breaking,
etc.
High
speed High Sheer Bar (nominal 3,300 feet per minute [1,006
meters per minute] blade peripheral tip speed) for significant
work input to create intimate dispersions of minute components
and break up tight agglomerates.
Ultra
high speed High Sheer Bar(nominal 5,000 feet per minute [1,525
meters per minute] blade peripheral tip speed) for very significant
work input to create streak free dispersions of minute components
and colors. Able to break up tight agglomerates; falls just
below a mill in capability. |
| Sanitary/corrosion
resistant options: |
| What
internal polish is required? |
|
|
| What
external polish is required? |
|
|
| Should
the carbon steel wrap plates on the vessel exterior near
the trunnions be clad in 304 stainless steel? |
|
|
| Support
frame material of construction: |
|
(If stainless, see below) |
| If
stainless, specify finish: |
| |
| Even
if the support frames are carbon steel, should the support
frames including motor(s), piping, etc. be enclosed with
stainless steel sheet metal walls? |
|
|
| Should
only the base plate (which is bolted to the floor) of the
support frames be made of 304 stainless steel to prevent
long term corrosion as cleaning solutions seep under over
the years and start to "bleed" rust? |
|
|
| Electrical
Ratings and Controls |
| Line
voltage available? |
|
Other:
|
| |
| Motor
ratings required? |
|
Other (please specify):
|
| Junction
Box? |
|
|
| For
explosion proof installations please specify class and division
required per NEC/NFPA or provide hazardous solvents and/or
powders involved for Gemco to suggest proper rating. |
Please
describe:
|
Electrical
ratings on the control panel (which can often be located in
the next room and rated as dust tight as opposed to explosion
proof to save cost and provide easier access)
Note: Unless the unit is shipped with a set of safety
gates, the panel will be shipped loose for remote wall installation
outside the customer supplied safety barrier. |
| Control
panel electrical rating required? |
|
|
| Should
we add any of the following components? |
| Push
button control station (start/stop/job but not starters,
transformers, lights, maintenance timer, etc.)?
|
| Full
control panel with starters, control voltage transformer,
running lights, maintenance timer, etc.?
|
| Settable
counter for vessel rotation?
|
| Settable
timer for vessel rotation?
|
| Settable
timer for High Sheer Bar rotation?
|
| RPM
indicator for vessel speed?
|
| RPM
indicator for High Sheer Bar speed?
|
| PLC
or PC interface for data logging and/or control (please define)? |
|
|
|
|
|
Loading
/ Unloading & Material Handling |
|
Do
you load
or, unload
with drums? |
|
Are
you interested in our Gemcomatic, an automated drum
loading/unloading system built into the machine?
|
|
|
|
Do
you load with drums and unload into bulk hoppers
or, bins?
(We can offer drum loading system that will discharge into hoppers). |
|
Do
you bulk load from above and bulk discharge below? |
|
|
|
Should
we provide an automatic positioning system to always stop
in the vertical up and vertical down positions? |
|
|
|
Should
we provide a flexible, retractable sleeve or boot on the
discharge valve to extend and mate with the loading/unloading
port? |
|
|
|
|
|
Thank you. We have all the information we need to begin specifying
your blending equipment equipment. Please click the submit
button to send your specifications.
|
|
|